Plan8 fttrusses 8 ft40 ft30 ftEndwall10 ft4:12girts 24"
ft

The truss span

ft

Along the sidewall

ft

Grade to the eave

:12

Rise per foot of run

ft

Down the sidewalls — your design

ft

From your truss drawing

Yours to choose — not checked

ft

Below grade, per your building department

6x6 posts, 14 ft each

16posts

Trusses

6

Roof panels

28

Wall panels

48

It counts the frame; it does not design it

Post size, how deep the posts go, the truss spacing and the trusses themselves decide whether this building stands up to your snow and wind, and none of them is this page's to choose. Post-frame trusses come stamped for a spacing; headers that carry trusses between posts need sizing; the post depth turns on frost line, soil and uplift. Ring your building department before you dig.

The frame

Posts, 6x66 down each sidewall 8 ft apart, 2 across each endwall between the corners; 10 ft of eave plus 4 ft in the ground
16 × 14 ft
Trusses30 ft span, 8 ft apart — one at each gable end
6
Skirt board, treatedOne row round the bottom, where the steel meets the ground
140 ft
Wall girts5 rows round the walls, plus 2 shortening rows up each gable — openings not taken off
748 ft
Purlins10 rows a side, one piece a truss bay — 840 ft with the rake overhangs
100 × 8 ft

The steel

Roof panels14 a side, eave edge to ridge — the metal roofing calculator adds the overhang into the gutter, the trim and the screws
28 × 16 ft 11 in
Sidewall panelsSkirt board to eave
28 × 10 ft
Endwall panels4 at 15 ft, 4 at 14 ft, 4 at 13 ft, 4 at 12 ft, 4 at 11 ft — each at its taller edge, the rake cut on site
20
Steel area1,417 of roof and 1,550 of wall, gables included
2,967 sq ft

Checks

All 3 checks passShow the numbers
  • Trusses line up with the posts — passesEvery truss lands on a pair of posts.
  • Posts come in a stocked length — passesEach post is 14 ft, eave height plus embedment.
  • At least 3:12 for exposed-fastener panels — passesThis roof is 4:12, steep enough for lapped exposed-fastener panels without lap sealant (IRC R905.10.2).

These check the layout's arithmetic and the 2021 IRC's minimum slope for metal panels (R905.10.2) — defaults, not law, and nothing about whether a post or a truss is big enough.