How deep should blown-in insulation be for R-49?

R-49 takes about 14" of blown cellulose or 19 5/8" of blown fiberglass, settled. Depths for every attic R-value, and why the bag's chart has the last word.

R-49 takes about 14" of blown cellulose, or 19 5/8" of blown fiberglass, measured settled.

Over a 1,000 sq ft attic that is 1167 cu ft of cellulose — R-49 sits inside the R-30 to R-60 range the Department of Energy recommends for attics.

How that is worked out

  1. Depth is the R-value you want divided by the R-value per inch of the material.
  2. Settled cellulose runs about R-3.5 an inch (published figures range 3.2–3.8), so R-49 ÷ 3.5 = 14.0".
  3. Loose fiberglass is fluffier, about R-2.5 an inch (2.2–2.9), so R-49 ÷ 2.5 = 19.6" — the same R-value needs more of it.

Settled depth of loose fill by R-value

Settled depth of loose fill by R-value
R-valueCelluloseFiberglassCellulose per 1,000 sq ft
R-195 7/16"7 5/8"452 cu ft
R-308 9/16"12"714 cu ft
R-3810 7/8"15 3/16"905 cu ft
R-4412 9/16"17 5/8"1048 cu ft
R-4914"19 5/8"1167 cu ft
R-6017 1/8"24"1429 cu ft

Worth knowing

  • R-per-inch is a property of the product, not a constant: the figures here are round numbers inside the published ranges. The bag you buy states its own, and its coverage chart — installed depth, settled depth and bags per 1,000 sq ft at each R-value — is the authority.
  • Blow to the installed depth on the chart, not the settled one. Loose fill settles after it goes in, and the R-value is rated at the settled depth.
  • Which R-value you want is set by your climate zone and the local energy code. The Department of Energy's range for attics runs from R-30 in the warmest zones to R-60 in the coldest.
  • Seal the air leaks in the ceiling first — around light fixtures, the attic hatch, plumbing and wiring holes. Warm air moving through insulation carries the heat straight past it.